Commercial Air Purification Systems​

Commercial Air Purification Systems

Voltage: 110V/250V
Energy: 45 Watts
Number of Tubes: 8
Tube Size: F
Capacity: Up to 15,000 cfm
Application: The AtmosAir 508FC Bipolar Ionization system is intended to be mounted in the supply duct or air handler of a heating, cooling, or ventilating system. The size and number of 508FC ionization systems is dependent upon the airflow, size of the space, and severity of the pollution and odors.

Voltage: 110V/220V
Energy: 45 Watts
Number of Tubes:
 5
Tube Size: E/F
Capacity: 8,000/10,000 cfm
Application: In duct unit for larger central HVAC systems. Ideal for office buildings, hospitals, schools, nursing homes, childcare facilities, locker rooms, training facilities, stadiums, food processing facilities, manufacturing plants and sewage treatment plants.

Voltage: 120V
Energy: 5 Watts
# of Ionization Tubes: 1/2
Tube Size: C/D/E/F
Capacity: 2,500/5,000 CFM
Application: The Matterhorn 1000/1002 ionization system is intended to be mounted in the supply duct or air handler of a heating, cooling, or ventilating system. The size and number of ionization systems is dependent upon the airflow, size of the space, and severity of the pollution and odors.

Voltage: 115/240VAC
Energy Use: 5 watts
Number of Tubes: One (1)
Tube Size: C(8”) D (10”) E (15”)
Capacity: up to 2400CFM
Application: The AtmosAir FC100 ionization system is intended to be mounted in the supply discharge in smaller air handling systems such as fan coils, heat pumps and other unitary type systems. The system can be integrated on an OEM basis, or a retrofit package is also available. Access to the unit’s control panel is provided. The unit will be calibrated at the factory per AtmosAir recommendations or the contractor will calibrate the ionization setting to attain ion level readings of between 350 and 1,500 negative ions/cm3 in the space.

Voltage: 12 VAC
Energy Use: 5 watts
Number of Tubes: .One (1)
Tube Size: B (3”)
Capacity: Up to 1400 CFM
Application: The AtmosAir FC-400 ionization system is intended to be mounted in the supply discharge in smaller air handling systems such as fan coil, heat pump and other unitary type systems. The system can be integrated on an OEM basis or a retrofit package is also provided. The unit will be calibrated at the factory per AtmosAir recommendations to attain ion level readings of
between 350 and1,500 –ions/cm3.

Voltage: 12 VAC
Energy Use: 5 watts
Number of Tubes: .One (1)
Tube Size: B (3”)
Capacity: Up to 1400 CFM
Application: The AtmosAir FC-400FM ionization system is intended to be flush-mounted in the supply discharge in smaller air handling systems such as fan coil, heat pump and other unitary type systems. The system can be integrated on an OEM basis or a retrofit package is also provided. The unit will be calibrated at the factory per AtmosAir recommendations to attain ion level readings of between 350 and 1,500 –ions/cm3

Voltage: 120 VAC
Energy Use: 45 watts
Number of Tubes: One (1)
Tube Size: B (3”)
Capacity: Up to 100 CFM
Application: The AtmosAir Rainier Summit is a standalone self contained compact unit designed to increase ionization levels to restore indoor air to its natural state where no pollution or contaminants exist. The Rainier’s patented active ionization technology has been rigorously tested and scientifically proven to be extremely effective at reducing harmful particulates, irritating volatile organic compounds (VOC’s) and odors as well as killing off mold, bacteria, viruses and germs in the air and on surfaces.

Voltage: 110 V
Energy Use: 260 watts
Number of Tubes: 1/2
Tube Size: E
Capacity: Up to 500 cfm
Application:The AtmosAir 700 series consists of a locking,
wall-mountable enclosure equipped with an ionization system, blower fan, and distribution ducting, custom-designed and sized for the application. The 700 series provides air purification and
odor remediation to spaces without an existing
HVAC or air distribution system. The 700 series
can be used in various commercial and industrial
applications, including wastewater, sewage,
smoking, refuse, chemical odors or air quality
issues.

Residential Air Purificiation Systems

Voltage: 12 VAC
Energy Use: 5 watts
Number of Tubes: .One (1)
Tube Size: B (3”)
Capacity: Up to 1400 CFM
Application: The AtmosAir FC-400 ionization system is intended to be mounted in the supply discharge in smaller air handling systems such as fan coil, heat pump and other unitary type systems. The system can be integrated on an OEM basis or a retrofit package is also provided. The unit will be calibrated at the factory per AtmosAir recommendations to attain ion level readings of
between 350 and1,500 –ions/cm3.

Voltage: 120V
Energy: 5 Watts
# of Ionization Tubes: 1/2
Tube Size: C/D/E/F
Capacity: 2,500/5,000 CFM
Application: The Matterhorn 1000/1002 ionization system is intended to be mounted in the supply duct or air handler of a heating, cooling, or ventilating system. The size and number of ionization systems is dependent upon the airflow, size of the space, and severity of the pollution and odors.

Voltage: 12 VAC
Energy Use: 5 watts
Number of Tubes: .One (1)
Tube Size: B (3”)
Capacity: Up to 1400 CFM
Application: The AtmosAir FC-400FM ionization system is intended to be flush-mounted in the supply discharge in smaller air handling systems such as fan coil, heat pump and other unitary type systems. The system can be integrated on an OEM basis or a retrofit package is also provided. The unit will be calibrated at the factory per AtmosAir recommendations to attain ion level readings of between 350 and 1,500 –ions/cm3

Voltage: 120 VAC
Energy Use: 45 watts
Number of Tubes: One (1)
Tube Size: B (3”)
Capacity: Up to 100 CFM
Application: The AtmosAir Rainier Summit is a standalone self contained compact unit designed to increase ionization levels to restore indoor air to its natural state where no pollution or contaminants exist. The Rainier’s patented active ionization technology has been rigorously tested and scientifically proven to be extremely effective at reducing harmful particulates, irritating volatile organic compounds (VOC’s) and odors as well as killing off mold, bacteria, viruses and germs in the air and on surfaces.